This site requires Cookies enabled in your browser for login.
Updating ...
WaterNet Home
WaterNet
for
pour le
Canada
Menu
WaterNet
Home
GWFO
Home
Catalogue
Master Index
Data
Centre
X
Find Data By Variable Find Data By Site, Facility, or Deployable Show Near-realtime Telemetry (7 day)
Collections
X
Defaults
Select All
Websites
X
Global Water Futures Observatories (GWFO) Global Water Futures (GWF) Global Institute for Water Security (GIWS) International Network of Alpine Research Catchment Hydrology
Legacy Research Programs
X
Changing Cold Regions Network (CCRN) Drought Research Initiative (DRI) International Network of Alpine Research Catchment Hydrology (Legacy Site) Improving Processes & Parameterization for Prediction in Cold Regions Hydrology (IP3) The Mackenzie Global Energy and Water Cycle Experiment (GEWEX) Study (MAGS)
Legacy sites
Map
Utilities
X
Account Settings Create a New Record Record List Alias List Editor
Edit Data Centre
Data Types
. . .
X
Clear
Select All
Advanced Search
Go to Top⇡
Related items loading ...
Fetching Chart ...
Publication Additional Information Download
Publication Type
Journal Article
Authorship
Zhang, Y., Guo, T., & Xu, C.
Title
A Systematic Study on Transit Time and Its Impact on Accuracy of Concentration Measured by Microfluidic Devices
Year
2020
Publication Outlet
Sensors, 20(1), 14.
DOI
https://doi.org/10.3390/s20010014
Citation
Zhang, Y., Guo, T., & Xu, C. (2020). A Systematic Study on Transit Time and Its Impact on Accuracy of Concentration Measured by Microfluidic Devices. Sensors, 20(1), 14. https://doi.org/10.3390/s20010014
Abstract
Gating or threshold selection is very important in analyzing data from a microflow cytometer, which is especially critical in analyzing weak signals from particles/cells with small sizes. It has been reported that using the amplitude gating alone may result in false positive events in analyzing data with a poor signal-to-noise ratio. Transit time (τ) can be set as a gating threshold along with side-scattered light or fluorescent light signals in the detection of particles/cells using a microflow cytometer. In this study, transit time of microspheres was studied systematically when the microspheres passed through a laser beam in a microflow cytometer and side-scattered light was detected. A clear linear relationship between the inverse of the average transit time and total flow rate was found. Transit time was used as another gate (other than the amplitude of side-scattering signals) to distinguish real scattering signals from noise. It was shown that the relative difference of the measured microsphere concentration can be reduced significantly from the range of 3.43%–8.77% to the range of 8.42%–111.76% by employing both amplitude and transit time as gates in analysis of collected scattering data. By using optimized transit time and amplitude gate thresholds, a good correlation with the traditional hemocytometer-based particle counting was achieved (R2 > 0.94). The obtained results suggest that the transit time could be used as another gate together with the amplitude gate to improve measurement accuracy of particle/cell concentration for microfluidic devices.
Program Affiliations
GWF: Global Water Futures
Project Affiliations
GWF-SSSWQM: Sensors and Sensing Systems for Water Quality Monitoring
Publication Stage
Published
Additional Information
Sensors
Download Links
https://doi.org/10.3390/s20010014
© 2026 - WaterNet Version 2026-07-24
Global Water Futures Observatories
Powered by
G W F Net
T-2021-11-14-X1WeZwbX2LHkOhUd7vPmpfVA Publication 1.0