This site requires Cookies enabled in your browser for login.
Updating ...
WaterNet Home
WaterNet
for
pour le
Canada
Menu
WaterNet
Home
GWFO
Home
Master
List
Data
Centre
Collections
X
Defaults
Select All
Websites
X
Global Water Futures Observatories (GWFO) Global Water Futures (GWF) Global Institute for Water Security (GIWS) International Network of Alpine Research Catchment Hydrology
Legacy Research Programs
X
Changing Cold Regions Network (CCRN) Drought Research Initiative (DRI) International Network of Alpine Research Catchment Hydrology (Legacy Site) Improving Processes & Parameterization for Prediction in Cold Regions Hydrology (IP3) The Mackenzie Global Energy and Water Cycle Experiment (GEWEX) Study (MAGS)
Legacy sites
Map
Utilities
X
Account Settings Metadata Editor Record List Alias List Editor
Data Centre
Data Type Editor
. . .
X
Clear
Select All
Advanced Search
Go to Top⇡
Related items loading ...
Fetching Chart ...
Publication Additional Information Download
Publication Type
Journal Article
Authorship
Marcinek, S., Chapoulie, A., Salaün, P., Smith, S., Omanović, D.
Title
Revised application of copper ion selective electrode (Cu-ISE) in marine waters: A new meta-calibration approach
Year
2021
Publication Outlet
Talanta, 226, 122170
DOI
https://doi.org/10.1016/j.talanta.2021.122170
Citation
Marcinek, S., Chapoulie, A., Salaün, P., Smith, S., Omanović, D. (2021). Revised application of copper ion selective electrode (Cu-ISE) in marine waters: A new meta-calibration approach. Talanta, 226, 122170. https://doi.org/10.1016/j.talanta.2021.122170
Abstract
Copper (Cu) is a bio-essential trace element that is of concerns due to its potential toxicity at concentrations commonly encountered in coastal waters. Here, we revisit the applicability of Cu(II) ion selective electrode (Cu-ISE) based on a jalpaite membrane for the measurement of Cufree in seawater. At high total Cu concentration (>0.1 mM), (near)Nernstian slope was obtained and determination of Cufree down to fM levels was possible. However, this slope decreases with decreasing total Cu concentration (e.g. 7 mV/decade at 15 nM total Cu) making the use of a common single calibration approach unreliable. To solve this problem, we carried out several calibrations at different levels of total Cu (15 nM - 1 mM) and ethylenediamine (EN: 5 μM - 15 mM) and fitted the calibration parameters (slope and intercept) as a function of total Cu using the Gompertz function (a meta-calibration approach). The derived empirical equations allowed the determination of Cufree at any total Cu concentration above 20 nM (determination of Cufree at lower total Cu levels is prevented by the dissolution of the electrode). We successfully tested this meta-calibration approach in UV digested seawater in presence of a synthetic ligand (EN), isolated natural organic matter (humic acid, HA) and in a natural estuarine sample. In each case, our meta-calibration approach provided a good agreement with modeled speciation data (Visual MINTEQ), while standard single approach failed. We provide here a new method for the direct determination of the free Cu ion concentration in seawater at levels relevant for coastal waters.
Program Affiliations
GWF: Global Water Futures
Project Affiliations
GWF-SSSWQM: Sensors and Sensing Systems for Water Quality Monitoring
Publication Stage
Published
Additional Information
Sensors
Download Links
https://doi.org/10.1016/j.talanta.2021.122170
© 2026 - WaterNet Version 2026-06-18
Global Water Futures Observatories
Powered by
G W F Net
T-2021-11-14-f10zCToZpnEaQzvr8mUXhcw Publication 1.0