This site requires Cookies enabled in your browser for login.
Updating ...
WaterNet Home
WaterNet
for
pour le
Canada
Menu
WaterNet
Home
GWFO
Home
Catalogue
Master Index
Data
Centre
X
Find Data By Variable Find Data By Site, Facility, or Deployable Show Near-realtime Telemetry (7 day)
Collections
X
Defaults
Select All
Websites
X
Global Water Futures Observatories (GWFO) Global Water Futures (GWF) Global Institute for Water Security (GIWS) International Network of Alpine Research Catchment Hydrology
Legacy Research Programs
X
Changing Cold Regions Network (CCRN) Drought Research Initiative (DRI) International Network of Alpine Research Catchment Hydrology (Legacy Site) Improving Processes & Parameterization for Prediction in Cold Regions Hydrology (IP3) The Mackenzie Global Energy and Water Cycle Experiment (GEWEX) Study (MAGS)
Legacy sites
Map
Utilities
X
Account Settings Create a New Record Record List Alias List Editor
Edit Data Centre
Data Types
. . .
X
Clear
Select All
Advanced Search
Go to Top⇡
Related items loading ...
Fetching Chart ...
Publication Additional Information Download
Publication Type
Journal Article
Authorship
Zhao Yichen, Yavari Kayvan, and Liu Juewen
Title
Critical Evaluation of Aptamer Binding for Biosensor Designs
Year
2022
Publication Outlet
TrAC, Trends in Analytical Chemistry, 146, 116480
DOI
https://doi.org/10.1016/j.trac.2021.116480
Citation
Yichen Zhao; Kayvan Yavari; and Juewen Liu, Critical Evaluation of Aptamer Binding for Biosensor Designs. TrAC, Trends in Analytical Chemistry, 146, 116480, https://doi.org/10.1016/j.trac.2021.116480 , 2022
Abstract
Over the last three decades, numerous aptamer-based biosensors have been reported. The basis of these sensors is the selective binding of target analytes by aptamers. In the last few years, a number of papers have been published questioning the binding ability of some popular aptamers such as those documented for As(III), ampicillin, chloramphenicol, isocarbophos, phorate and dopamine. In this article, these papers are reviewed, and the binding assays are described, which may provide possible reasons for obtaining false positive aptamers. Additionally, relevant aptamer selection methods and typical characterization steps are described. It is found that for small molecular targets, using an immobilized library might result in better aptamers. Furthermore, the importance of carefully designed controls to ensure the quality of binding assays is discussed, especially in the case of mutated nonbinding aptamers. Only then, with fully validated aptamers, can subsequent biosensor design bring about meaningful results.
Program Affiliations
GWF: Global Water Futures
Project Affiliations
GWF-SSSWQM: Sensors and Sensing Systems for Water Quality Monitoring
Publication Stage
Published
Additional Information
Sensors and Sensing Systems for Water Quality Monitoring
Download Links
https://doi.org/10.1016/j.trac.2021.116480
© 2026 - WaterNet Version 2026-07-24
Global Water Futures Observatories
Powered by
G W F Net
T-2022-11-03-W1CJY2v8ZDkG90sOAqQTnlw Publication 1.0