This site requires Cookies enabled in your browser for login.
Updating ...
WaterNet Home
WaterNet
for
pour le
Canada
Menu
WaterNet
Home
GWFO
Home
Catalogue
Master Index
Data
Centre
Collections
X
Defaults
Select All
Websites
X
Global Water Futures Observatories (GWFO) Global Water Futures (GWF) Global Institute for Water Security (GIWS) International Network of Alpine Research Catchment Hydrology
Legacy Research Programs
X
Changing Cold Regions Network (CCRN) Drought Research Initiative (DRI) International Network of Alpine Research Catchment Hydrology (Legacy Site) Improving Processes & Parameterization for Prediction in Cold Regions Hydrology (IP3) The Mackenzie Global Energy and Water Cycle Experiment (GEWEX) Study (MAGS)
Legacy sites
Map
Utilities
X
Account Settings Create a New Record Record List Alias List Editor
Edit Data Centre
Data Types
. . .
X
Clear
Select All
Advanced Search
Go to Top⇡
Related items loading ...
Fetching Chart ...
Publication Additional Information Download
Publication Type
Journal Article
Authorship
Huang, Po-Jung Jimmy; Liu, Juewen
Title
Simultaneous Detection of L-Lactate and D-Glucose Using DNA Aptamers in Human Blood Serum
Year
2023
Publication Outlet
John Wiley & Sons, Ltd, Angewandte Chemie International Edition, Vol. 62, Iss. 12, e202212879
DOI
https://doi.org/10.1002/anie.202212879
ISSN
1433-7851
Citation
Huang, Po-Jung Jimmy; Liu, Juewen (2023) Simultaneous Detection of L-Lactate and D-Glucose Using DNA Aptamers in Human Blood Serum, John Wiley & Sons, Ltd, Angewandte Chemie International Edition, Vol. 62, Iss. 12, e202212879, https://doi.org/10.1002/anie.202212879
Abstract
L-lactate is a key metabolite indicative of physiological states, glycolysis pathways, and various diseases such as sepsis, heart attack, lactate acidosis, and cancer. Detection of lactate has been relying on a few enzymes that need additional oxidants. In this work, DNA aptamers for L-lactate were obtained using a library-immobilization selection method and the highest affinity aptamer reached a Kd of 0.43 mM as determined using isothermal titration calorimetry. The aptamers showed up to 50-fold selectivity for L-lactate over D-lactate and had little responses to other closely related analogs such as pyruvate or 3-hydroxybutyrate. A fluorescent biosensor based on the strand displacement method showed a limit of detection of 0.55 mM L-lactate, and the sensor worked in 90 % serum. Simultaneous detection of L-lactate and D-glucose in the same solution was achieved. This work has broadened the scope of aptamers to simple metabolites and provided a useful probe for continuous and multiplexed monitoring.
Program Affiliations
GWF: Global Water Futures
Project Affiliations
GWF-SSSWQM: Sensors and Sensing Systems for Water Quality Monitoring
Publication Stage
Published
Additional Information
Keywords: Aptamers; Biosensors; Fluorescence; Glucose; Lactate
Download Links
https://doi.org/10.1002/anie.202212879
© 2026 - WaterNet Version 2026-07-16
Global Water Futures Observatories
Powered by
G W F Net
T-2025-03-27-O1Hjku3DeK02DUqhp9HSUeA Publication 1.0