This site requires Cookies enabled in your browser for login.
Updating ...
WaterNet Home
WaterNet
for
pour le
Canada
Menu
WaterNet
Home
GWFO
Home
Catalogue
Master Index
Data
Centre
Collections
X
Defaults
Select All
Websites
X
Global Water Futures Observatories (GWFO) Global Water Futures (GWF) Global Institute for Water Security (GIWS) International Network of Alpine Research Catchment Hydrology
Legacy Research Programs
X
Changing Cold Regions Network (CCRN) Drought Research Initiative (DRI) International Network of Alpine Research Catchment Hydrology (Legacy Site) Improving Processes & Parameterization for Prediction in Cold Regions Hydrology (IP3) The Mackenzie Global Energy and Water Cycle Experiment (GEWEX) Study (MAGS)
Legacy sites
Map
Utilities
X
Account Settings Create a New Record Record List Alias List Editor
Edit Data Centre
Data Types
. . .
X
Clear
Select All
Advanced Search
Go to Top⇡
Related items loading ...
Fetching Chart ...
Publication Additional Information Download
Publication Type
Journal Article
Authorship
Zubiarrain-Laserna, A., Angizi, S., Akbar, M. A., Divigalpitiya, R., Selvaganapathy, P. R., Kruse, P.
Title
Detection of free chlorine in water using graphene-like carbon based chemiresistive sensors
Year
2022
Publication Outlet
RSC Publishing, RSC Advances 2025, Issue 36, Issue in Progress
DOI
https://doi.org/10.1039/D1RA08264G
Abstract
Free chlorine is the most commonly used water disinfectant. Measuring its concentration during and after water treatment is crucial to ensure its effectiveness. However, many of the existing methods do not allow for continuous on-line monitoring. Here we demonstrate a solid state chemiresistive sensor using graphene-like carbon (GLC) that overcomes that issue. GLC films that were either bare or non-covalently functionalized with the redox-active phenyl-capped aniline tetramer (PCAT) were successfully employed to quantify aqueous free chlorine, although functionalized devices showed better performance. The response of the sensors to increasing concentrations of free chlorine followed a Langmuir adsorption isotherm in the two tested ranges: 0.01–0.2 ppm and 0.2–1.4 ppm. The limit of detection was estimated to be 1 ppb, permitting the detection of breaches in chlorine filters. The devices respond to decreasing levels of free chlorine without the need for a reset, allowing for the continuous monitoring of fluctuations in the concentration. The maximum sensor response and saturation concentration were found to depend on the thickness of the GLC film. Hence, the sensitivity and dynamic range of the sensors can be tailored to different applications by adjusting the thickness of the films. Tap water samples from a residential area were tested using these sensors, which showed good agreement with standard colorimetric measurement methods. The devices did not suffer from interferences in the presence of ions commonly found in drinking water. Overall, these sensors are a cost-effective option for the continuous automated monitoring of free chlorine in drinking water.
Program Affiliations
GWF: Global Water Futures
Project Affiliations
GWF-SSSWQM: Sensors and Sensing Systems for Water Quality Monitoring
Publication Stage
Published
Download Links
https://doi.org/10.1039/D1RA08264G